Compare Modules
Select two modules to overlay their IV/PV curves, diff every CEC spec, and check whether a string of each fits your inverter's DC voltage window.
Select Module A above to get started — add Module B to see a full diff.
Inverter (optional — needed for the pass/fail check)
String Voc(cold) = (Voc,ref + βoc·(Tlow−25)) × N. String Vmp(hot) uses a
Vmp temperature coefficient approximated as half of γ (Pmax tempco) — the same
current/voltage split convention documented for
vmp_share in the Analyzer's MPPT-limiting check
(apps/api/iv_diagnosis.py): degradation (and, here,
temperature-driven power change) is assumed to load half onto voltage and half onto
current. A flag compares the result against the inverter's Vdc max and
Vmppt,min = max(Mppt low, Vac·√2).