Apollo Renewables Inc Apollo-M754BH-395BB

Mono-c-Si
395 W Pmax
36.98 V Voc
13.7 A Isc
30.84 V Vmp
12.81 A Imp
20.36 % eff.
0.7798 FF
54 cells
IV & PV Curves at STC (1000 W/m², 25 °C)
IV Curves at Multiple Conditions

Irradiance sweep at 25 °C

Temperature sweep at 1000 W/m²

Single-Diode Model Parameters

Source: California Energy Commission module list · retrieved via SAM library · energy.ca.gov · All data sources

Parameter Symbol Value Unit
Nameplate (STC)
STC Power STC 395.06 W
PTC Power PTC 370.1 W
Open-circuit voltage V_oc_ref 36.98 V
Short-circuit current I_sc_ref 13.7 A
Max-power voltage V_mp_ref 30.84 V
Max-power current I_mp_ref 12.81 A
Fill factor FF 0.7798 —
Efficiency (STC) η 20.36 %
Temperature Coefficients
Isc temperature coefficient alpha_sc 0.006192 A/°C
Voc temperature coefficient beta_oc -0.098219 V/°C
Pmax temperature coefficient gamma_r -0.3609 %/°C
NOCT T_NOCT 43.2 °C
Single-Diode (De Soto) Parameters
Modified ideality factor a_ref 1.40013 V
Light-generated current (ref) I_L_ref 13.71793 A
Saturation current (ref) I_o_ref 4.53e-11 A
Series resistance R_s 0.14088 Ω
Shunt resistance (ref) R_sh_ref 107.663 Ω
Cells in series N_s 54 —
CEC Adjust factor Adjust 12.6594 %
Additional Model Sources
Source Model type Fit quality Citation
CEC module list (via SAM library) Default CEC / De Soto single-diode — https://www.energy.ca.gov/media/2367
Sandia PVsyst single-diode fit PVsyst single-diode NMBE Pmp-0.057 Sandia National Laboratories — PVsyst single-diode parameter translation. See data/pvsyst_params.README.md. https://pvpmc.sandia.gov/

Was this page useful?

© 2026 PV Ivy. All Rights Reserved.