Boviet Solar Technology Co. Ltd. BVM7610M-435-H-HC

Mono-c-Si
436 W Pmax
41.2 V Voc
13.32 A Isc
34.8 V Vmp
12.53 A Imp
20.76 % eff.
0.7946 FF
60 cells
IV & PV Curves at STC (1000 W/m², 25 °C)
IV Curves at Multiple Conditions

Irradiance sweep at 25 °C

Temperature sweep at 1000 W/m²

Single-Diode Model Parameters

Source: California Energy Commission module list · retrieved via SAM library · energy.ca.gov · All data sources

Parameter Symbol Value Unit
Nameplate (STC)
STC Power STC 436.044 W
PTC Power PTC 408.9 W
Open-circuit voltage V_oc_ref 41.2 V
Short-circuit current I_sc_ref 13.32 A
Max-power voltage V_mp_ref 34.8 V
Max-power current I_mp_ref 12.53 A
Fill factor FF 0.7946 —
Efficiency (STC) η 20.76 %
Temperature Coefficients
Isc temperature coefficient alpha_sc 0.002398 A/°C
Voc temperature coefficient beta_oc -0.340724 V/°C
Pmax temperature coefficient gamma_r -0.352 %/°C
NOCT T_NOCT 42.9 °C
Single-Diode (De Soto) Parameters
Modified ideality factor a_ref 1.53408 V
Light-generated current (ref) I_L_ref 13.3308 A
Saturation current (ref) I_o_ref 2.84e-11 A
Series resistance R_s 0.12708 Ω
Shunt resistance (ref) R_sh_ref 157.066 Ω
Cells in series N_s 60 —
CEC Adjust factor Adjust -65.0337 %
Additional Model Sources
Source Model type Fit quality Citation
CEC module list (via SAM library) Default CEC / De Soto single-diode — https://www.energy.ca.gov/media/2367
Sandia PVsyst single-diode fit PVsyst single-diode NMBE Pmp-0.3364 Sandia National Laboratories — PVsyst single-diode parameter translation. See data/pvsyst_params.README.md. https://pvpmc.sandia.gov/
Actions
Module Specifications
Technology Mono-c-Si
Bifacial No
BIPV No
Cells in series 60
Module area 2.1 m²
NOCT 42.9 °C
Temp. coefficient of Pmax -0.352 %/°C
Temp. coefficient of Voc -0.827 %/°C
Temp. coefficient of Isc 0.018 %/°C
CEC list On the 23 Jun 2026 list
Parameters from 16 Nov 2022 list
Annual degradation 0.6%/yr
Measured Data
No measured data yet for this module.
Related Models
Similar Modules

Other manufacturers, same technology and cell count, power within 3 %.

Was this page useful?