CSI Solar Co. Ltd. CS1Y-385MS
Mono-c-Si
385
W Pmax
51.7
V Voc
9.78
A Isc
42.9
V Vmp
8.97
A Imp
19.73
% eff.
0.7611
FF
78
cells
IV & PV Curves at STC (1000 W/m², 25 °C)
IV Curves at Multiple Conditions
Irradiance sweep at 25 °C
Temperature sweep at 1000 W/m²
Single-Diode Model Parameters
Source: California Energy Commission module list · retrieved via SAM library · energy.ca.gov · All data sources
| Parameter | Symbol | Value | Unit |
|---|---|---|---|
| Nameplate (STC) | |||
| STC Power | STC | 384.813 | W |
| PTC Power | PTC | 361.8 | W |
| Open-circuit voltage | V_oc_ref | 51.7 | V |
| Short-circuit current | I_sc_ref | 9.78 | A |
| Max-power voltage | V_mp_ref | 42.9 | V |
| Max-power current | I_mp_ref | 8.97 | A |
| Fill factor | FF | 0.7611 | — |
| Efficiency (STC) | η | 19.73 | % |
| Temperature Coefficients | |||
| Isc temperature coefficient | alpha_sc | 0.004205 | A/°C |
| Voc temperature coefficient | beta_oc | -0.141141 | V/°C |
| Pmax temperature coefficient | gamma_r | -0.347 | %/°C |
| NOCT | T_NOCT | 42.9 | °C |
| Single-Diode (De Soto) Parameters | |||
| Modified ideality factor | a_ref | 1.94782 | V |
| Light-generated current (ref) | I_L_ref | 9.80758 | A |
| Saturation current (ref) | I_o_ref | 2.77e-11 | A |
| Series resistance | R_s | 0.30624 | Ω |
| Shunt resistance (ref) | R_sh_ref | 108.583 | Ω |
| Cells in series | N_s | 78 | — |
| CEC Adjust factor | Adjust | 8.3456 | % |
Additional Model Sources
| Source | Model type | Fit quality | Citation |
|---|---|---|---|
| CEC module list (via SAM library) Default | CEC / De Soto single-diode | — | https://www.energy.ca.gov/media/2367 |
| Sandia PVsyst single-diode fit | PVsyst single-diode | NMBE Pmp0.0688 | Sandia National Laboratories — PVsyst single-diode parameter translation. See data/pvsyst_params.README.md. https://pvpmc.sandia.gov/ |
Actions
Module Specifications
Technology
Mono-c-Si
Bifacial
No
BIPV
No
Cells in series
78
Module area
1.95 m²
NOCT
42.9 °C
Temp. coefficient of Pmax
-0.347 %/°C
Temp. coefficient of Voc
-0.273 %/°C
Temp. coefficient of Isc
0.043 %/°C
CEC list
On the 23 Jun 2026 list
Parameters from
16 Nov 2022 list
Annual degradation
0.55%/yr
Measured Data
No measured data yet for this module.
Related Models
Similar Modules
Other manufacturers, same technology and cell count, power within 3 %.
- Shenglong PV-tech (Cambodia) Co. LTD GLSM385M-78H-V 384.9 W 51.8 V Voc
- Hansol Technics Co. Ltd. HS385UE-AN1 385.2 W 50.1 V Voc
- Hansol Technics Co. Ltd. HS380UE-AN1 380.1 W 49.7 V Voc
- Shenglong PV-tech (Cambodia) Co. LTD GLSM380M-78H-V 380.1 W 51.5 V Voc
- LONGi Green Energy Technology Co. Ltd. LR6-78HBD-390M 390.2 W 51.9 V Voc
- LONGi Green Energy Technology Co. Ltd. LR6-78HBD-395M 395.0 W 52.1 V Voc