Hanwha Q CELLS (Qidong) HSL60P6-PC-3-275

Multi-c-Si
275 W Pmax
38.7 V Voc
9.31 A Isc
31.3 V Vmp
8.79 A Imp
16.47 % eff.
0.7636 FF
60 cells
IV & PV Curves at STC (1000 W/m², 25 °C)
IV Curves at Multiple Conditions

Irradiance sweep at 25 °C

Temperature sweep at 1000 W/m²

Single-Diode Model Parameters

Source: California Energy Commission module list · retrieved via SAM library · energy.ca.gov · All data sources

Parameter Symbol Value Unit
Nameplate (STC)
STC Power STC 275.127 W
PTC Power PTC 250.1 W
Open-circuit voltage V_oc_ref 38.7 V
Short-circuit current I_sc_ref 9.31 A
Max-power voltage V_mp_ref 31.3 V
Max-power current I_mp_ref 8.79 A
Fill factor FF 0.7636 —
Efficiency (STC) η 16.47 %
Temperature Coefficients
Isc temperature coefficient alpha_sc 0.005139 A/°C
Voc temperature coefficient beta_oc -0.125078 V/°C
Pmax temperature coefficient gamma_r -0.4309 %/°C
NOCT T_NOCT 45.5 °C
Single-Diode (De Soto) Parameters
Modified ideality factor a_ref 1.58072 V
Light-generated current (ref) I_L_ref 9.31329 A
Saturation current (ref) I_o_ref 2.16e-10 A
Series resistance R_s 0.31117 Ω
Shunt resistance (ref) R_sh_ref 880.199 Ω
Cells in series N_s 60 —
CEC Adjust factor Adjust 7.9961 %
Additional Model Sources
Source Model type Fit quality Citation
CEC module list (via SAM library) Default CEC / De Soto single-diode — https://www.energy.ca.gov/media/2367
Sandia PVsyst single-diode fit PVsyst single-diode NMBE Pmp-0.0423 Sandia National Laboratories — PVsyst single-diode parameter translation. See data/pvsyst_params.README.md. https://pvpmc.sandia.gov/
Actions
Module Specifications
Technology Multi-c-Si
Bifacial No
BIPV No
Cells in series 60
Module area 1.67 m²
Dimensions 1.67 × 1.0 m
NOCT 45.5 °C
Temp. coefficient of Pmax -0.431 %/°C
Temp. coefficient of Voc -0.323 %/°C
Temp. coefficient of Isc 0.055 %/°C
CEC list On the 23 Jun 2026 list
Parameters from 16 Nov 2022 list
Annual degradation 0.5%/yr
Measured Data
No measured data yet for this module.
Related Models
Similar Modules

Other manufacturers, same technology and cell count, power within 3 %.

Was this page useful?

© 2026 PV Ivy. All Rights Reserved.