Hanwha SolarOne (Qidong) SF190-27-P200

Multi-c-Si
200 W Pmax
32.8 V Voc
8.24 A Isc
26.9 V Vmp
7.44 A Imp
13.4 % eff.
0.7405 FF
54 cells
IV & PV Curves at STC (1000 W/m², 25 °C)
IV Curves at Multiple Conditions

Irradiance sweep at 25 °C

Temperature sweep at 1000 W/m²

Single-Diode Model Parameters

Source: California Energy Commission module list · retrieved via SAM library · energy.ca.gov · All data sources

Parameter Symbol Value Unit
Nameplate (STC)
STC Power STC 200.136 W
PTC Power PTC 177.7 W
Open-circuit voltage V_oc_ref 32.8 V
Short-circuit current I_sc_ref 8.24 A
Max-power voltage V_mp_ref 26.9 V
Max-power current I_mp_ref 7.44 A
Fill factor FF 0.7405 —
Efficiency (STC) η 13.4 %
Temperature Coefficients
Isc temperature coefficient alpha_sc 0.003214 A/°C
Voc temperature coefficient beta_oc -0.106272 V/°C
Pmax temperature coefficient gamma_r -0.47 %/°C
NOCT T_NOCT 47.0 °C
Single-Diode (De Soto) Parameters
Modified ideality factor a_ref 1.42178 V
Light-generated current (ref) I_L_ref 8.2679 A
Saturation current (ref) I_o_ref 7.44e-10 A
Series resistance R_s 0.22501 Ω
Shunt resistance (ref) R_sh_ref 66.458 Ω
Cells in series N_s 54 —
CEC Adjust factor Adjust 20.6007 %
Additional Model Sources
Source Model type Fit quality Citation
CEC module list (via SAM library) Default CEC / De Soto single-diode — https://www.energy.ca.gov/media/2367
Sandia PVsyst single-diode fit PVsyst single-diode NMBE Pmp0.2599 Sandia National Laboratories — PVsyst single-diode parameter translation. See data/pvsyst_params.README.md. https://pvpmc.sandia.gov/
Actions
Module Specifications
Technology Multi-c-Si
Bifacial No
BIPV No
Cells in series 54
Module area 1.494 m²
Dimensions 1.494 × 1.0 m
NOCT 47.0 °C
Temp. coefficient of Pmax -0.470 %/°C
Temp. coefficient of Voc -0.324 %/°C
Temp. coefficient of Isc 0.039 %/°C
CEC list On the 23 Jun 2026 list
Parameters from 16 Nov 2022 list
Annual degradation 0.5%/yr
Measured Data
No measured data yet for this module.
Related Models
Similar Modules

Other manufacturers, same technology and cell count, power within 3 %.

Was this page useful?

© 2026 PV Ivy. All Rights Reserved.