Jinko Solar Co. Ltd JKM295M-72

Mono-c-Si
295 W Pmax
46.0 V Voc
8.59 A Isc
37.6 V Vmp
7.85 A Imp
15.21 % eff.
0.747 FF
72 cells
IV & PV Curves at STC (1000 W/m², 25 °C)
IV Curves at Multiple Conditions

Irradiance sweep at 25 °C

Temperature sweep at 1000 W/m²

Single-Diode Model Parameters

Source: California Energy Commission module list · retrieved via SAM library · energy.ca.gov · All data sources

Parameter Symbol Value Unit
Nameplate (STC)
STC Power STC 295.16 W
PTC Power PTC 265.6 W
Open-circuit voltage V_oc_ref 46.0 V
Short-circuit current I_sc_ref 8.59 A
Max-power voltage V_mp_ref 37.6 V
Max-power current I_mp_ref 7.85 A
Fill factor FF 0.747 —
Efficiency (STC) η 15.21 %
Temperature Coefficients
Isc temperature coefficient alpha_sc 0.006279 A/°C
Voc temperature coefficient beta_oc -0.164404 V/°C
Pmax temperature coefficient gamma_r -0.4388 %/°C
NOCT T_NOCT 46.7 °C
Single-Diode (De Soto) Parameters
Modified ideality factor a_ref 1.98908 V
Light-generated current (ref) I_L_ref 8.61301 A
Saturation current (ref) I_o_ref 7.44e-10 A
Series resistance R_s 0.32129 Ω
Shunt resistance (ref) R_sh_ref 119.963 Ω
Cells in series N_s 72 —
CEC Adjust factor Adjust 8.4616 %
Additional Model Sources
Source Model type Fit quality Citation
CEC module list (via SAM library) Default CEC / De Soto single-diode — https://www.energy.ca.gov/media/2367
Sandia PVsyst single-diode fit PVsyst single-diode NMBE Pmp1.2162 Sandia National Laboratories — PVsyst single-diode parameter translation. See data/pvsyst_params.README.md. https://pvpmc.sandia.gov/
Actions
Module Specifications
Technology Mono-c-Si
Bifacial No
BIPV No
Cells in series 72
Module area 1.94 m²
Dimensions 1.956 × 0.992 m
NOCT 46.7 °C
Temp. coefficient of Pmax -0.439 %/°C
Temp. coefficient of Voc -0.357 %/°C
Temp. coefficient of Isc 0.073 %/°C
CEC list On the 23 Jun 2026 list
Parameters from 16 Nov 2022 list
Annual degradation 0.55%/yr