Jinko Solar Co. Ltd JKM360M-72

Multi-c-Si
360 W Pmax
48.0 V Voc
9.51 A Isc
39.5 V Vmp
9.12 A Imp
19.63 % eff.
0.7892 FF
72 cells
IV & PV Curves at STC (1000 W/m², 25 °C)
IV Curves at Multiple Conditions

Irradiance sweep at 25 °C

Temperature sweep at 1000 W/m²

Single-Diode Model Parameters

Source: California Energy Commission module list · retrieved via SAM library · energy.ca.gov · All data sources

Parameter Symbol Value Unit
Nameplate (STC)
STC Power STC 360.24 W
PTC Power PTC 331.5 W
Open-circuit voltage V_oc_ref 48.0 V
Short-circuit current I_sc_ref 9.51 A
Max-power voltage V_mp_ref 39.5 V
Max-power current I_mp_ref 9.12 A
Fill factor FF 0.7892 —
Efficiency (STC) η 19.63 %
Temperature Coefficients
Isc temperature coefficient alpha_sc 0.006182 A/°C
Voc temperature coefficient beta_oc -0.14784 V/°C
Pmax temperature coefficient gamma_r -0.409 %/°C
NOCT T_NOCT 44.9 °C
Single-Diode (De Soto) Parameters
Modified ideality factor a_ref 1.94147 V
Light-generated current (ref) I_L_ref 9.60541 A
Saturation current (ref) I_o_ref 1.76e-10 A
Series resistance R_s 0.29462 Ω
Shunt resistance (ref) R_sh_ref 9071.79 Ω
Cells in series N_s 72 —
CEC Adjust factor Adjust 11.0962 %
Additional Model Sources
Source Model type Fit quality Citation
CEC module list (via SAM library) Default CEC / De Soto single-diode — https://www.energy.ca.gov/media/2367
Sandia PVsyst single-diode fit PVsyst single-diode NMBE Pmp-0.5097 Sandia National Laboratories — PVsyst single-diode parameter translation. See data/pvsyst_params.README.md. https://pvpmc.sandia.gov/
Actions
Module Specifications
Technology Multi-c-Si
Bifacial No
BIPV No
Cells in series 72
Module area 1.835 m²
Dimensions 1.924 × 0.954 m
NOCT 44.9 °C
Temp. coefficient of Pmax -0.409 %/°C
Temp. coefficient of Voc -0.308 %/°C
Temp. coefficient of Isc 0.065 %/°C
CEC list On the 23 Jun 2026 list
Parameters from 16 Nov 2022 list
Annual degradation 0.55%/yr
Measured Data
No measured data yet for this module.
Related Models
Similar Modules

Other manufacturers, same technology and cell count, power within 3 %.

Was this page useful?

© 2026 PV Ivy. All Rights Reserved.