LG Electronics Inc. LG230P1W

Multi-c-Si
218 W Pmax
36.4 V Voc
8.26 A Isc
29.5 V Vmp
7.39 A Imp
13.24 % eff.
0.7251 FF
60 cells
IV & PV Curves at STC (1000 W/m², 25 °C)
IV Curves at Multiple Conditions

Irradiance sweep at 25 °C

Temperature sweep at 1000 W/m²

Single-Diode Model Parameters

Source: California Energy Commission module list · retrieved via SAM library · energy.ca.gov · All data sources

Parameter Symbol Value Unit
Nameplate (STC)
STC Power STC 218.005 W
PTC Power PTC 204.7 W
Open-circuit voltage V_oc_ref 36.4 V
Short-circuit current I_sc_ref 8.26 A
Max-power voltage V_mp_ref 29.5 V
Max-power current I_mp_ref 7.39 A
Fill factor FF 0.7251 —
Efficiency (STC) η 13.24 %
Temperature Coefficients
Isc temperature coefficient alpha_sc 0.003139 A/°C
Voc temperature coefficient beta_oc -0.123396 V/°C
Pmax temperature coefficient gamma_r -0.505 %/°C
NOCT T_NOCT 45.4 °C
Single-Diode (De Soto) Parameters
Modified ideality factor a_ref 1.63398 V
Light-generated current (ref) I_L_ref 8.29687 A
Saturation current (ref) I_o_ref 1.64e-09 A
Series resistance R_s 0.28738 Ω
Shunt resistance (ref) R_sh_ref 64.385 Ω
Cells in series N_s 60 —
CEC Adjust factor Adjust 22.8307 %
Additional Model Sources
Source Model type Fit quality Citation
CEC module list (via SAM library) Default CEC / De Soto single-diode — https://www.energy.ca.gov/media/2367
Sandia PVsyst single-diode fit PVsyst single-diode NMBE Pmp0.1134 Sandia National Laboratories — PVsyst single-diode parameter translation. See data/pvsyst_params.README.md. https://pvpmc.sandia.gov/
Actions
Module Specifications
Technology Multi-c-Si
Bifacial No
BIPV No
Cells in series 60
Module area 1.646 m²
Dimensions 1.658 × 0.993 m
NOCT 45.4 °C
Temp. coefficient of Pmax -0.505 %/°C
Temp. coefficient of Voc -0.339 %/°C
Temp. coefficient of Isc 0.038 %/°C
CEC list On the 23 Jun 2026 list
Parameters from 16 Nov 2022 list
Annual degradation 0.33%/yr
Measured Data
No measured data yet for this module.
Related Models
Similar Modules

Other manufacturers, same technology and cell count, power within 3 %.

Was this page useful?