LG Electronics Inc. LG305N1T-A5

Mono-c-Si
305 W Pmax
40.6 V Voc
10.04 A Isc
32.6 V Vmp
9.37 A Imp
17.91 % eff.
0.7494 FF
60 cells
IV & PV Curves at STC (1000 W/m², 25 °C)
IV Curves at Multiple Conditions

Irradiance sweep at 25 °C

Temperature sweep at 1000 W/m²

Single-Diode Model Parameters

Source: California Energy Commission module list · retrieved via SAM library · energy.ca.gov · All data sources

Parameter Symbol Value Unit
Nameplate (STC)
STC Power STC 305.462 W
PTC Power PTC 280.5 W
Open-circuit voltage V_oc_ref 40.6 V
Short-circuit current I_sc_ref 10.04 A
Max-power voltage V_mp_ref 32.6 V
Max-power current I_mp_ref 9.37 A
Fill factor FF 0.7494 —
Efficiency (STC) η 17.91 %
Temperature Coefficients
Isc temperature coefficient alpha_sc 0.002008 A/°C
Voc temperature coefficient beta_oc -0.10962 V/°C
Pmax temperature coefficient gamma_r -0.36 %/°C
NOCT T_NOCT 47.3 °C
Single-Diode (De Soto) Parameters
Modified ideality factor a_ref 1.4724 V
Light-generated current (ref) I_L_ref 10.0638 A
Saturation current (ref) I_o_ref 1.04e-11 A
Series resistance R_s 0.37469 Ω
Shunt resistance (ref) R_sh_ref 157.758 Ω
Cells in series N_s 60 —
CEC Adjust factor Adjust 1.1986 %
Additional Model Sources
Source Model type Fit quality Citation
CEC module list (via SAM library) Default CEC / De Soto single-diode — https://www.energy.ca.gov/media/2367
Sandia PVsyst single-diode fit PVsyst single-diode NMBE Pmp0.0261 Sandia National Laboratories — PVsyst single-diode parameter translation. See data/pvsyst_params.README.md. https://pvpmc.sandia.gov/
Actions
Module Specifications
Technology Mono-c-Si
Bifacial No
BIPV No
Cells in series 60
Module area 1.706 m²
Dimensions 1.706 × 1.0 m
NOCT 47.3 °C
Temp. coefficient of Pmax -0.360 %/°C
Temp. coefficient of Voc -0.270 %/°C
Temp. coefficient of Isc 0.020 %/°C
CEC list On the 23 Jun 2026 list
Parameters from 16 Nov 2022 list
Annual degradation 0.33%/yr