LONGi Green Energy Technology Co. Ltd. LR6-78HBD-400M
Mono-c-Si
Bifacial
400
W Pmax
52.4
V Voc
9.88
A Isc
43.8
V Vmp
9.14
A Imp
18.97
% eff.
0.7733
FF
78
cells
IV & PV Curves at STC (1000 W/m², 25 °C)
IV Curves at Multiple Conditions
Irradiance sweep at 25 °C
Temperature sweep at 1000 W/m²
Single-Diode Model Parameters
Source: California Energy Commission module list · retrieved via SAM library · energy.ca.gov · All data sources
| Parameter | Symbol | Value | Unit |
|---|---|---|---|
| Nameplate (STC) | |||
| STC Power | STC | 400.332 | W |
| PTC Power | PTC | 373.7 | W |
| Open-circuit voltage | V_oc_ref | 52.4 | V |
| Short-circuit current | I_sc_ref | 9.88 | A |
| Max-power voltage | V_mp_ref | 43.8 | V |
| Max-power current | I_mp_ref | 9.14 | A |
| Fill factor | FF | 0.7733 | — |
| Efficiency (STC) | η | 18.97 | % |
| Temperature Coefficients | |||
| Isc temperature coefficient | alpha_sc | 0.004644 | A/°C |
| Voc temperature coefficient | beta_oc | -0.140432 | V/°C |
| Pmax temperature coefficient | gamma_r | -0.337 | %/°C |
| NOCT | T_NOCT | 44.8 | °C |
| Single-Diode (De Soto) Parameters | |||
| Modified ideality factor | a_ref | 1.95675 | V |
| Light-generated current (ref) | I_L_ref | 9.89983 | A |
| Saturation current (ref) | I_o_ref | 2.23e-11 | A |
| Series resistance | R_s | 0.27215 | Ω |
| Shunt resistance (ref) | R_sh_ref | 135.602 | Ω |
| Cells in series | N_s | 78 | — |
| CEC Adjust factor | Adjust | 8.2828 | % |
Additional Model Sources
| Source | Model type | Fit quality | Citation |
|---|---|---|---|
| CEC module list (via SAM library) Default | CEC / De Soto single-diode | — | https://www.energy.ca.gov/media/2367 |
| Sandia PVsyst single-diode fit | PVsyst single-diode | NMBE Pmp-0.0175 | Sandia National Laboratories — PVsyst single-diode parameter translation. See data/pvsyst_params.README.md. https://pvpmc.sandia.gov/ |
Actions
Module Specifications
Technology
Mono-c-Si
Bifacial
Yes
BIPV
No
Cells in series
78
Module area
2.11 m²
NOCT
44.8 °C
Temp. coefficient of Pmax
-0.337 %/°C
Temp. coefficient of Voc
-0.268 %/°C
Temp. coefficient of Isc
0.047 %/°C
CEC list
On the 23 Jun 2026 list
Parameters from
16 Nov 2022 list
Annual degradation
0.55%/yr
Measured Data
No measured data yet for this module.
Related Models
Similar Modules
Other manufacturers, same technology and cell count, power within 3 %.
- Hansol Technics Co. Ltd. HS400UE-AN1 400.3 W 51.3 V Voc
- CSI Solar Co. Ltd. CS1Y-400MS 400.2 W 52.3 V Voc
- Shenglong PV-tech (Cambodia) Co. LTD GLSM400M-78H-V 400.2 W 52.7 V Voc
- Hansol Technics Co. Ltd. HS400UE-JH2 400.0 W 52.2 V Voc
- Jinko Solar Co. Ltd JKM405M-78H-TV 405.0 W 51.55 V Voc
- Shenglong PV-tech (Cambodia) Co. LTD GLSM405M-78H-V 405.1 W 52.9 V Voc
Was this page useful?
Thanks. Every note is read.
© 2026 PV Ivy. All Rights Reserved.