Mission Solar Energy LLC MSE310MC1A

Multi-c-Si
310 W Pmax
44.9 V Voc
9.08 A Isc
36.4 V Vmp
8.52 A Imp
15.9 % eff.
0.7607 FF
72 cells
IV & PV Curves at STC (1000 W/m², 25 °C)
IV Curves at Multiple Conditions

Irradiance sweep at 25 °C

Temperature sweep at 1000 W/m²

Single-Diode Model Parameters

Source: California Energy Commission module list · retrieved via SAM library · energy.ca.gov · All data sources

Parameter Symbol Value Unit
Nameplate (STC)
STC Power STC 310.128 W
PTC Power PTC 273.2 W
Open-circuit voltage V_oc_ref 44.9 V
Short-circuit current I_sc_ref 9.08 A
Max-power voltage V_mp_ref 36.4 V
Max-power current I_mp_ref 8.52 A
Fill factor FF 0.7607 —
Efficiency (STC) η 15.9 %
Temperature Coefficients
Isc temperature coefficient alpha_sc 0.004134 A/°C
Voc temperature coefficient beta_oc -0.170261 V/°C
Pmax temperature coefficient gamma_r -0.4936 %/°C
NOCT T_NOCT 48.2 °C
Single-Diode (De Soto) Parameters
Modified ideality factor a_ref 1.9577 V
Light-generated current (ref) I_L_ref 9.08555 A
Saturation current (ref) I_o_ref 9.86e-10 A
Series resistance R_s 0.33021 Ω
Shunt resistance (ref) R_sh_ref 540.453 Ω
Cells in series N_s 72 —
CEC Adjust factor Adjust 4.2848 %
Additional Model Sources
Source Model type Fit quality Citation
CEC module list (via SAM library) Default CEC / De Soto single-diode — https://www.energy.ca.gov/media/2367
Sandia PVsyst single-diode fit PVsyst single-diode NMBE Pmp-0.0046 Sandia National Laboratories — PVsyst single-diode parameter translation. See data/pvsyst_params.README.md. https://pvpmc.sandia.gov/
Actions
Module Specifications
Technology Multi-c-Si
Bifacial No
BIPV No
Cells in series 72
Module area 1.95 m²
Dimensions 1.97 × 0.99 m
NOCT 48.2 °C
Temp. coefficient of Pmax -0.494 %/°C
Temp. coefficient of Voc -0.379 %/°C
Temp. coefficient of Isc 0.046 %/°C
CEC list On the 23 Jun 2026 list
Parameters from 16 Nov 2022 list
Annual degradation 0.58%/yr
Measured Data
No measured data yet for this module.
Related Models
Similar Modules

Other manufacturers, same technology and cell count, power within 3 %.

Was this page useful?