Mission Solar Energy LLC MSE340SQ6S

Mono-c-Si
342 W Pmax
46.57 V Voc
9.67 A Isc
38.25 V Vmp
8.93 A Imp
17.73 % eff.
0.7585 FF
72 cells
IV & PV Curves at STC (1000 W/m², 25 °C)
IV Curves at Multiple Conditions

Irradiance sweep at 25 °C

Temperature sweep at 1000 W/m²

Single-Diode Model Parameters

Source: California Energy Commission module list · retrieved via SAM library · energy.ca.gov · All data sources

Parameter Symbol Value Unit
Nameplate (STC)
STC Power STC 341.572 W
PTC Power PTC 313.3 W
Open-circuit voltage V_oc_ref 46.57 V
Short-circuit current I_sc_ref 9.67 A
Max-power voltage V_mp_ref 38.25 V
Max-power current I_mp_ref 8.93 A
Fill factor FF 0.7585 —
Efficiency (STC) η 17.73 %
Temperature Coefficients
Isc temperature coefficient alpha_sc 0.004448 A/°C
Voc temperature coefficient beta_oc -0.130396 V/°C
Pmax temperature coefficient gamma_r -0.38 %/°C
NOCT T_NOCT 45.5 °C
Single-Diode (De Soto) Parameters
Modified ideality factor a_ref 1.81137 V
Light-generated current (ref) I_L_ref 9.69373 A
Saturation current (ref) I_o_ref 6.37e-11 A
Series resistance R_s 0.31314 Ω
Shunt resistance (ref) R_sh_ref 127.599 Ω
Cells in series N_s 72 —
CEC Adjust factor Adjust 12.9727 %
Additional Model Sources
Source Model type Fit quality Citation
CEC module list (via SAM library) Default CEC / De Soto single-diode — https://www.energy.ca.gov/media/2367
Sandia PVsyst single-diode fit PVsyst single-diode NMBE Pmp0.059 Sandia National Laboratories — PVsyst single-diode parameter translation. See data/pvsyst_params.README.md. https://pvpmc.sandia.gov/
Actions
Module Specifications
Technology Mono-c-Si
Bifacial No
BIPV No
Cells in series 72
Module area 1.926 m²
Dimensions 1.967 × 0.979 m
NOCT 45.5 °C
Temp. coefficient of Pmax -0.380 %/°C
Temp. coefficient of Voc -0.280 %/°C
Temp. coefficient of Isc 0.046 %/°C
CEC list On the 23 Jun 2026 list
Parameters from 16 Nov 2022 list
Annual degradation 0.58%/yr
Measured Data