REC Solar REC325PEM 72

Mono-c-Si
325 W Pmax
45.6 V Voc
9.32 A Isc
37.5 V Vmp
8.67 A Imp
16.2 % eff.
0.765 FF
72 cells
IV & PV Curves at STC (1000 W/m², 25 °C)
IV Curves at Multiple Conditions

Irradiance sweep at 25 °C

Temperature sweep at 1000 W/m²

Single-Diode Model Parameters

Source: California Energy Commission module list · retrieved via SAM library · energy.ca.gov · All data sources

Parameter Symbol Value Unit
Nameplate (STC)
STC Power STC 325.125 W
PTC Power PTC 292.9 W
Open-circuit voltage V_oc_ref 45.6 V
Short-circuit current I_sc_ref 9.32 A
Max-power voltage V_mp_ref 37.5 V
Max-power current I_mp_ref 8.67 A
Fill factor FF 0.765 —
Efficiency (STC) η 16.2 %
Temperature Coefficients
Isc temperature coefficient alpha_sc 0.003914 A/°C
Voc temperature coefficient beta_oc -0.144552 V/°C
Pmax temperature coefficient gamma_r -0.452 %/°C
NOCT T_NOCT 46.2 °C
Single-Diode (De Soto) Parameters
Modified ideality factor a_ref 1.91136 V
Light-generated current (ref) I_L_ref 9.33298 A
Saturation current (ref) I_o_ref 3.96e-10 A
Series resistance R_s 0.27738 Ω
Shunt resistance (ref) R_sh_ref 199.132 Ω
Cells in series N_s 72 —
CEC Adjust factor Adjust 15.8634 %
Additional Model Sources
Source Model type Fit quality Citation
CEC module list (via SAM library) Default CEC / De Soto single-diode — https://www.energy.ca.gov/media/2367
Sandia PVsyst single-diode fit PVsyst single-diode NMBE Pmp-0.3373 Sandia National Laboratories — PVsyst single-diode parameter translation. See data/pvsyst_params.README.md. https://pvpmc.sandia.gov/
Actions
Module Specifications
Technology Mono-c-Si
Bifacial No
BIPV No
Cells in series 72
Module area 2.007 m²
Dimensions 2.005 × 1.001 m
NOCT 46.2 °C
Temp. coefficient of Pmax -0.452 %/°C
Temp. coefficient of Voc -0.317 %/°C
Temp. coefficient of Isc 0.042 %/°C
CEC list Not on the 23 Jun 2026 list
Last listed 16 Nov 2022
Parameters from 16 Nov 2022 list
Annual degradation 0.5%/yr
Measured Data
No measured data yet for this module.
Related Models
Similar Modules

Other manufacturers, same technology and cell count, power within 3 %.

Was this page useful?