Solaria Corporation Solaria PowerXT-345R-PD
Same test data as Solaria PowerXT-345R-AC. CEC lists each frame, color and backsheet version as its own listing.
Irradiance sweep at 25 °C
Temperature sweep at 1000 W/m²
Source: California Energy Commission module list · retrieved via SAM library · energy.ca.gov · All data sources
| Parameter | Symbol | Value | Unit |
|---|---|---|---|
| Nameplate (STC) | |||
| STC Power | STC | 343.805 | W |
| PTC Power | PTC | 313.5 | W |
| Open-circuit voltage | V_oc_ref | 46.9 | V |
| Short-circuit current | I_sc_ref | 9.46 | A |
| Max-power voltage | V_mp_ref | 38.5 | V |
| Max-power current | I_mp_ref | 8.93 | A |
| Fill factor | FF | 0.7749 | — |
| Efficiency (STC) | η | 18.99 | % |
| Temperature Coefficients | |||
| Isc temperature coefficient | alpha_sc | 0.004598 | A/°C |
| Voc temperature coefficient | beta_oc | -0.144874 | V/°C |
| Pmax temperature coefficient | gamma_r | -0.4202 | %/°C |
| NOCT | T_NOCT | 47.1 | °C |
| Single-Diode (De Soto) Parameters | |||
| Modified ideality factor | a_ref | 1.89449 | V |
| Light-generated current (ref) | I_L_ref | 9.46452 | A |
| Saturation current (ref) | I_o_ref | 1.66e-10 | A |
| Series resistance | R_s | 0.30528 | Ω |
| Shunt resistance (ref) | R_sh_ref | 638.358 | Ω |
| Cells in series | N_s | 360 | — |
| CEC Adjust factor | Adjust | 10.6312 | % |
The CEC list gives 360 cells in series, which puts 0.13 V on each cell. A silicon cell gives 0.55 to 0.80 V, so PV Ivy uses 72 cells in series for the .PAN file and Similar Modules, found from Voc per cell and the CEC fit's ideality factor.
2 listings with identical nameplate test data, one per frame, color or backsheet version.
- Solaria PowerXT-345R-AC Main listing
- Solaria PowerXT-345R-PD This page
Other manufacturers, same technology and cell count, power within 3 %.
Was this page useful?
Thanks. Every note is read.
© 2026 PV Ivy. All Rights Reserved.