Solaria Corporation Solaria PowerXT-365R-PD-L
Same test data as Solaria PowerXT-365R-AC and 1 other listing. CEC lists each frame, color and backsheet version as its own listing.
Irradiance sweep at 25 °C
Temperature sweep at 1000 W/m²
Source: California Energy Commission module list · retrieved via SAM library · energy.ca.gov · All data sources
| Parameter | Symbol | Value | Unit |
|---|---|---|---|
| Nameplate (STC) | |||
| STC Power | STC | 365.484 | W |
| PTC Power | PTC | 332.4 | W |
| Open-circuit voltage | V_oc_ref | 48.0 | V |
| Short-circuit current | I_sc_ref | 9.58 | A |
| Max-power voltage | V_mp_ref | 39.9 | V |
| Max-power current | I_mp_ref | 9.16 | A |
| Fill factor | FF | 0.7948 | — |
| Efficiency (STC) | η | 20.19 | % |
| Temperature Coefficients | |||
| Isc temperature coefficient | alpha_sc | 0.004656 | A/°C |
| Voc temperature coefficient | beta_oc | -0.148272 | V/°C |
| Pmax temperature coefficient | gamma_r | -0.4202 | %/°C |
| NOCT | T_NOCT | 47.1 | °C |
| Single-Diode (De Soto) Parameters | |||
| Modified ideality factor | a_ref | 1.94344 | V |
| Light-generated current (ref) | I_L_ref | 9.58 | A |
| Saturation current (ref) | I_o_ref | 1.8e-10 | A |
| Series resistance | R_s | 0.22078 | Ω |
| Shunt resistance (ref) | R_sh_ref | 999999.8 | Ω |
| Cells in series | N_s | 36 | — |
| CEC Adjust factor | Adjust | 11.1845 | % |
The CEC list gives 36 cells in series, which puts 1.33 V on each cell. A silicon cell gives 0.55 to 0.80 V, so PV Ivy uses 72 cells in series for the .PAN file and Similar Modules, found from the CEC count times 2.
3 listings with identical nameplate test data, one per frame, color or backsheet version.
- Solaria PowerXT-365R-AC Main listing
- Solaria PowerXT-365R-PD
- Solaria PowerXT-365R-PD-L This page
Other manufacturers, same technology and cell count, power within 3 %.
Was this page useful?
Thanks. Every note is read.