SunPower SPR-MAX3-410-BLK-R

Mono-c-Si
410 W Pmax
40.68 V Voc
12.63 A Isc
35.1 V Vmp
11.68 A Imp
21.58 % eff.
0.7979 FF
56 cells
IV & PV Curves at STC (1000 W/m², 25 °C)
IV Curves at Multiple Conditions

Irradiance sweep at 25 °C

Temperature sweep at 1000 W/m²

Single-Diode Model Parameters

Source: California Energy Commission module list · retrieved via SAM library · energy.ca.gov · All data sources

Parameter Symbol Value Unit
Nameplate (STC)
STC Power STC 409.968 W
PTC Power PTC 387.4 W
Open-circuit voltage V_oc_ref 40.68 V
Short-circuit current I_sc_ref 12.63 A
Max-power voltage V_mp_ref 35.1 V
Max-power current I_mp_ref 11.68 A
Fill factor FF 0.7979 —
Efficiency (STC) η 21.58 %
Temperature Coefficients
Isc temperature coefficient alpha_sc 0.005684 A/°C
Voc temperature coefficient beta_oc -0.095191 V/°C
Pmax temperature coefficient gamma_r -0.28 %/°C
NOCT T_NOCT 46.0 °C
Single-Diode (De Soto) Parameters
Modified ideality factor a_ref 1.42164 V
Light-generated current (ref) I_L_ref 12.64424 A
Saturation current (ref) I_o_ref 4.52e-12 A
Series resistance R_s 0.08169 Ω
Shunt resistance (ref) R_sh_ref 72.46 Ω
Cells in series N_s 112 —
CEC Adjust factor Adjust 6.8827 %

The CEC list gives 112 cells in series, which puts 0.36 V on each cell. A silicon cell gives 0.55 to 0.80 V, so PV Ivy uses 56 cells in series for the .PAN file and Similar Modules, found from half the CEC count (it counts every half cell).

Additional Model Sources
Source Model type Fit quality Citation
CEC module list (via SAM library) Default CEC / De Soto single-diode — https://www.energy.ca.gov/media/2367
Sandia PVsyst single-diode fit PVsyst single-diode NMBE Pmp-6.1056 Sandia National Laboratories — PVsyst single-diode parameter translation. See data/pvsyst_params.README.md. https://pvpmc.sandia.gov/
Actions
Module Specifications
Technology Mono-c-Si
Bifacial No
BIPV No
Cells in series 56 (inferred, CEC lists 112)
Module area 1.9 m²
NOCT 46.0 °C
Temp. coefficient of Pmax -0.280 %/°C
Temp. coefficient of Voc -0.234 %/°C
Temp. coefficient of Isc 0.045 %/°C
CEC list On the 23 Jun 2026 list
Parameters from 23 Jun 2026 list
Measured Data
No measured data yet for this module.
Related Models
Similar Modules

Other manufacturers, same technology and cell count, power within 3 %.

Was this page useful?