Hanwha Q CELLS Q.PEAK DUO XL-G11.3/BFG 585

Mono-c-Si Bifacial
585 W Pmax
53.6 V Voc
13.57 A Isc
45.1 V Vmp
12.97 A Imp
21.99 % eff.
0.8042 FF
78 cells
IV & PV Curves at STC (1000 W/m², 25 °C)
IV Curves at Multiple Conditions

Irradiance sweep at 25 °C

Temperature sweep at 1000 W/m²

Single-Diode Model Parameters

Source: California Energy Commission module list · retrieved via SAM library · energy.ca.gov · All data sources

Parameter Symbol Value Unit
Nameplate (STC)
STC Power STC 584.947 W
PTC Power PTC 540.4 W
Open-circuit voltage V_oc_ref 53.6 V
Short-circuit current I_sc_ref 13.57 A
Max-power voltage V_mp_ref 45.1 V
Max-power current I_mp_ref 12.97 A
Fill factor FF 0.8042 —
Efficiency (STC) η 21.99 %
Temperature Coefficients
Isc temperature coefficient alpha_sc 0.006785 A/°C
Voc temperature coefficient beta_oc -0.15008 V/°C
Pmax temperature coefficient gamma_r -0.372 %/°C
NOCT T_NOCT 47.0 °C
Single-Diode (De Soto) Parameters
Modified ideality factor a_ref 2.07314 V
Light-generated current (ref) I_L_ref 13.7114 A
Saturation current (ref) I_o_ref 8.02e-11 A
Series resistance R_s 0.16207 Ω
Shunt resistance (ref) R_sh_ref 388.818 Ω
Cells in series N_s 78 —
CEC Adjust factor Adjust 11.7626 %
Additional Model Sources
Source Model type Fit quality Citation
CEC module list (via SAM library) Default CEC / De Soto single-diode — https://www.energy.ca.gov/media/2367
Sandia PVsyst single-diode fit PVsyst single-diode NMBE Pmp-0.1274 Sandia National Laboratories — PVsyst single-diode parameter translation. See data/pvsyst_params.README.md. https://pvpmc.sandia.gov/
Actions
Module Specifications
Technology Mono-c-Si
Bifacial Yes
BIPV No
Cells in series 78
Module area 2.66 m²
NOCT 47.0 °C
Temp. coefficient of Pmax -0.372 %/°C
Temp. coefficient of Voc -0.280 %/°C
Temp. coefficient of Isc 0.050 %/°C
CEC list On the 23 Jun 2026 list
Parameters from 16 Nov 2022 list
Annual degradation 0.5%/yr
Measured Data
No measured data yet for this module.