HYUNDAI ENERGY SOLUTIONS CO. LTD. HiS-M194SF

Multi-c-Si
193 W Pmax
33.1 V Voc
8.0 A Isc
26.4 V Vmp
7.3 A Imp
13.28 % eff.
0.7278 FF
54 cells
IV & PV Curves at STC (1000 W/m², 25 °C)
IV Curves at Multiple Conditions

Irradiance sweep at 25 °C

Temperature sweep at 1000 W/m²

Single-Diode Model Parameters

Source: California Energy Commission module list · retrieved via SAM library · energy.ca.gov · All data sources

Parameter Symbol Value Unit
Nameplate (STC)
STC Power STC 192.72 W
PTC Power PTC 175.4 W
Open-circuit voltage V_oc_ref 33.1 V
Short-circuit current I_sc_ref 8.0 A
Max-power voltage V_mp_ref 26.4 V
Max-power current I_mp_ref 7.3 A
Fill factor FF 0.7278 —
Efficiency (STC) η 13.28 %
Temperature Coefficients
Isc temperature coefficient alpha_sc 0.00312 A/°C
Voc temperature coefficient beta_oc -0.109892 V/°C
Pmax temperature coefficient gamma_r -0.477 %/°C
NOCT T_NOCT 43.6 °C
Single-Diode (De Soto) Parameters
Modified ideality factor a_ref 1.41273 V
Light-generated current (ref) I_L_ref 8.0306 A
Saturation current (ref) I_o_ref 5.12e-10 A
Series resistance R_s 0.35458 Ω
Shunt resistance (ref) R_sh_ref 92.693 Ω
Cells in series N_s 54 —
CEC Adjust factor Adjust 14.3998 %
Additional Model Sources
Source Model type Fit quality Citation
CEC module list (via SAM library) Default CEC / De Soto single-diode — https://www.energy.ca.gov/media/2367
Sandia PVsyst single-diode fit PVsyst single-diode NMBE Pmp0.0155 Sandia National Laboratories — PVsyst single-diode parameter translation. See data/pvsyst_params.README.md. https://pvpmc.sandia.gov/
Actions
Module Specifications
Technology Multi-c-Si
Bifacial No
BIPV No
Cells in series 54
Module area 1.451 m²
Dimensions 1.476 × 0.983 m
NOCT 43.6 °C
Temp. coefficient of Pmax -0.477 %/°C
Temp. coefficient of Voc -0.332 %/°C
Temp. coefficient of Isc 0.039 %/°C
CEC list On the 23 Jun 2026 list
Parameters from 16 Nov 2022 list
Annual degradation 0.54%/yr
Measured Data
No measured data yet for this module.
Related Models
Similar Modules

Other manufacturers, same technology and cell count, power within 3 %.

Was this page useful?

© 2026 PV Ivy. All Rights Reserved.