HYUNDAI ENERGY SOLUTIONS CO. LTD. HiS-M200SF

Multi-c-Si
200 W Pmax
33.6 V Voc
8.2 A Isc
26.7 V Vmp
7.5 A Imp
13.8 % eff.
0.7268 FF
54 cells
IV & PV Curves at STC (1000 W/m², 25 °C)
IV Curves at Multiple Conditions

Irradiance sweep at 25 °C

Temperature sweep at 1000 W/m²

Single-Diode Model Parameters

Source: California Energy Commission module list · retrieved via SAM library · energy.ca.gov · All data sources

Parameter Symbol Value Unit
Nameplate (STC)
STC Power STC 200.25 W
PTC Power PTC 180.9 W
Open-circuit voltage V_oc_ref 33.6 V
Short-circuit current I_sc_ref 8.2 A
Max-power voltage V_mp_ref 26.7 V
Max-power current I_mp_ref 7.5 A
Fill factor FF 0.7268 —
Efficiency (STC) η 13.8 %
Temperature Coefficients
Isc temperature coefficient alpha_sc 0.003198 A/°C
Voc temperature coefficient beta_oc -0.111552 V/°C
Pmax temperature coefficient gamma_r -0.477 %/°C
NOCT T_NOCT 43.6 °C
Single-Diode (De Soto) Parameters
Modified ideality factor a_ref 1.42883 V
Light-generated current (ref) I_L_ref 8.23038 A
Saturation current (ref) I_o_ref 4.83e-10 A
Series resistance R_s 0.36702 Ω
Shunt resistance (ref) R_sh_ref 99.062 Ω
Cells in series N_s 54 —
CEC Adjust factor Adjust 13.6276 %
Additional Model Sources
Source Model type Fit quality Citation
CEC module list (via SAM library) Default CEC / De Soto single-diode — https://www.energy.ca.gov/media/2367
Sandia PVsyst single-diode fit PVsyst single-diode NMBE Pmp-0.0135 Sandia National Laboratories — PVsyst single-diode parameter translation. See data/pvsyst_params.README.md. https://pvpmc.sandia.gov/
Actions
Module Specifications
Technology Multi-c-Si
Bifacial No
BIPV No
Cells in series 54
Module area 1.451 m²
Dimensions 1.476 × 0.983 m
NOCT 43.6 °C
Temp. coefficient of Pmax -0.477 %/°C
Temp. coefficient of Voc -0.332 %/°C
Temp. coefficient of Isc 0.039 %/°C
CEC list On the 23 Jun 2026 list
Parameters from 16 Nov 2022 list
Annual degradation 0.54%/yr
Measured Data
No measured data yet for this module.
Related Models
Similar Modules

Other manufacturers, same technology and cell count, power within 3 %.