HYUNDAI ENERGY SOLUTIONS CO. LTD. HiS-S233MG

Mono-c-Si
235 W Pmax
37.1 V Voc
8.2 A Isc
30.5 V Vmp
7.7 A Imp
14.52 % eff.
0.772 FF
60 cells
IV & PV Curves at STC (1000 W/m², 25 °C)
IV Curves at Multiple Conditions

Irradiance sweep at 25 °C

Temperature sweep at 1000 W/m²

Single-Diode Model Parameters

Source: California Energy Commission module list · retrieved via SAM library · energy.ca.gov · All data sources

Parameter Symbol Value Unit
Nameplate (STC)
STC Power STC 234.85 W
PTC Power PTC 205.9 W
Open-circuit voltage V_oc_ref 37.1 V
Short-circuit current I_sc_ref 8.2 A
Max-power voltage V_mp_ref 30.5 V
Max-power current I_mp_ref 7.7 A
Fill factor FF 0.772 —
Efficiency (STC) η 14.52 %
Temperature Coefficients
Isc temperature coefficient alpha_sc 0.002903 A/°C
Voc temperature coefficient beta_oc -0.137122 V/°C
Pmax temperature coefficient gamma_r -0.4974 %/°C
NOCT T_NOCT 47.0 °C
Single-Diode (De Soto) Parameters
Modified ideality factor a_ref 1.61896 V
Light-generated current (ref) I_L_ref 8.20444 A
Saturation current (ref) I_o_ref 9.06e-10 A
Series resistance R_s 0.24003 Ω
Shunt resistance (ref) R_sh_ref 443.062 Ω
Cells in series N_s 60 —
CEC Adjust factor Adjust 7.2826 %
Additional Model Sources
Source Model type Fit quality Citation
CEC module list (via SAM library) Default CEC / De Soto single-diode — https://www.energy.ca.gov/media/2367
Sandia PVsyst single-diode fit PVsyst single-diode NMBE Pmp0.0739 Sandia National Laboratories — PVsyst single-diode parameter translation. See data/pvsyst_params.README.md. https://pvpmc.sandia.gov/
Actions
Module Specifications
Technology Mono-c-Si
Bifacial No
BIPV No
Cells in series 60
Module area 1.617 m²
Dimensions 1.645 × 0.983 m
NOCT 47.0 °C
Temp. coefficient of Pmax -0.497 %/°C
Temp. coefficient of Voc -0.370 %/°C
Temp. coefficient of Isc 0.035 %/°C
CEC list On the 23 Jun 2026 list
Parameters from 16 Nov 2022 list
Annual degradation 0.54%/yr
Measured Data