HYUNDAI ENERGY SOLUTIONS CO. LTD. HiS-S350RI(BK)
Mono-c-Si
348
W Pmax
47.1
V Voc
9.6
A Isc
38.7
V Vmp
9.0
A Imp
17.77
% eff.
0.7703
FF
72
cells
Same test data as HiS-S350RI and 1 other listing. CEC lists each frame, color and backsheet version as its own listing.
IV & PV Curves at STC (1000 W/m², 25 °C)
IV Curves at Multiple Conditions
Irradiance sweep at 25 °C
Temperature sweep at 1000 W/m²
Single-Diode Model Parameters
Source: California Energy Commission module list · retrieved via SAM library · energy.ca.gov · All data sources
| Parameter | Symbol | Value | Unit |
|---|---|---|---|
| Nameplate (STC) | |||
| STC Power | STC | 348.3 | W |
| PTC Power | PTC | 317.2 | W |
| Open-circuit voltage | V_oc_ref | 47.1 | V |
| Short-circuit current | I_sc_ref | 9.6 | A |
| Max-power voltage | V_mp_ref | 38.7 | V |
| Max-power current | I_mp_ref | 9.0 | A |
| Fill factor | FF | 0.7703 | — |
| Efficiency (STC) | η | 17.77 | % |
| Temperature Coefficients | |||
| Isc temperature coefficient | alpha_sc | 0.004608 | A/°C |
| Voc temperature coefficient | beta_oc | -0.156372 | V/°C |
| Pmax temperature coefficient | gamma_r | -0.453 | %/°C |
| NOCT | T_NOCT | 45.6 | °C |
| Single-Diode (De Soto) Parameters | |||
| Modified ideality factor | a_ref | 1.98195 | V |
| Light-generated current (ref) | I_L_ref | 9.60787 | A |
| Saturation current (ref) | I_o_ref | 4.52e-10 | A |
| Series resistance | R_s | 0.27991 | Ω |
| Shunt resistance (ref) | R_sh_ref | 341.625 | Ω |
| Cells in series | N_s | 72 | — |
| CEC Adjust factor | Adjust | 11.4167 | % |
Additional Model Sources
| Source | Model type | Fit quality | Citation |
|---|---|---|---|
| CEC module list (via SAM library) Default | CEC / De Soto single-diode | — | https://www.energy.ca.gov/media/2367 |
| Sandia PVsyst single-diode fit | PVsyst single-diode | NMBE Pmp-0.5112 | Sandia National Laboratories — PVsyst single-diode parameter translation. See data/pvsyst_params.README.md. https://pvpmc.sandia.gov/ |
Actions
Module Specifications
Technology
Mono-c-Si
Bifacial
No
BIPV
No
Cells in series
72
Module area
1.96 m²
NOCT
45.6 °C
Temp. coefficient of Pmax
-0.453 %/°C
Temp. coefficient of Voc
-0.332 %/°C
Temp. coefficient of Isc
0.048 %/°C
CEC list
On the 23 Jun 2026 list
Parameters from
16 Nov 2022 list
Annual degradation
0.54%/yr
Measured Data
No measured data yet for this module.
Same Test Data
3 listings with identical nameplate test data, one per frame, color or backsheet version.
- HiS-S350RI Main listing
- HiS-S350KI(BK)
- HiS-S350RI(BK) This page
Related Models
Similar Modules
Other manufacturers, same technology and cell count, power within 3 %.
- CertainTeed CT350M00-01 Same test data as this module 348.3 W 47.1 V Voc
- Orb Energy Private Limited Orb350M72-15 347.9 W 49.0 V Voc
- Heliene 72M345 347.6 W 47.26 V Voc
- Mission Solar Energy LLC MSE345SQ4S 347.4 W 46.98 V Voc
- Jinko Solar Co. Ltd JKM350M-72B 349.6 W 47.5 V Voc
- Jinko Solar Co. Ltd JKM350M-72H 349.6 W 47.5 V Voc
Was this page useful?