JA Solar JAM6-60-240/SI

Mono-c-Si
240 W Pmax
37.49 V Voc
8.54 A Isc
30.56 V Vmp
7.85 A Imp
14.67 % eff.
0.7493 FF
60 cells
IV & PV Curves at STC (1000 W/m², 25 °C)
IV Curves at Multiple Conditions

Irradiance sweep at 25 °C

Temperature sweep at 1000 W/m²

Single-Diode Model Parameters

Source: California Energy Commission module list · retrieved via SAM library · energy.ca.gov · All data sources

Parameter Symbol Value Unit
Nameplate (STC)
STC Power STC 239.896 W
PTC Power PTC 212.9 W
Open-circuit voltage V_oc_ref 37.49 V
Short-circuit current I_sc_ref 8.54 A
Max-power voltage V_mp_ref 30.56 V
Max-power current I_mp_ref 7.85 A
Fill factor FF 0.7493 —
Efficiency (STC) η 14.67 %
Temperature Coefficients
Isc temperature coefficient alpha_sc 0.00544 A/°C
Voc temperature coefficient beta_oc -0.127354 V/°C
Pmax temperature coefficient gamma_r -0.4645 %/°C
NOCT T_NOCT 48.0 °C
Single-Diode (De Soto) Parameters
Modified ideality factor a_ref 1.63162 V
Light-generated current (ref) I_L_ref 8.55936 A
Saturation current (ref) I_o_ref 8.66e-10 A
Series resistance R_s 0.27222 Ω
Shunt resistance (ref) R_sh_ref 120.067 Ω
Cells in series N_s 60 —
CEC Adjust factor Adjust 15.7203 %
Additional Model Sources
Source Model type Fit quality Citation
CEC module list (via SAM library) Default CEC / De Soto single-diode — https://www.energy.ca.gov/media/2367
Sandia PVsyst single-diode fit PVsyst single-diode NMBE Pmp-0.2007 Sandia National Laboratories — PVsyst single-diode parameter translation. See data/pvsyst_params.README.md. https://pvpmc.sandia.gov/
Actions
Module Specifications
Technology Mono-c-Si
Bifacial No
BIPV No
Cells in series 60
Module area 1.635 m²
Dimensions 1.65 × 0.991 m
NOCT 48.0 °C
Temp. coefficient of Pmax -0.465 %/°C
Temp. coefficient of Voc -0.340 %/°C
Temp. coefficient of Isc 0.064 %/°C
CEC list On the 23 Jun 2026 list
Parameters from 16 Nov 2022 list
Annual degradation 0.55%/yr
Measured Data
No measured data yet for this module.
Related Models
Similar Modules

Other manufacturers, same technology and cell count, power within 3 %.

Was this page useful?

© 2026 PV Ivy. All Rights Reserved.