REC Solar REC280PE Z-Link-M

Mono-c-Si
280 W Pmax
38.3 V Voc
9.34 A Isc
31.7 V Vmp
8.84 A Imp
17.01 % eff.
0.7834 FF
60 cells
IV & PV Curves at STC (1000 W/m², 25 °C)
IV Curves at Multiple Conditions

Irradiance sweep at 25 °C

Temperature sweep at 1000 W/m²

Single-Diode Model Parameters

Source: California Energy Commission module list · retrieved via SAM library · energy.ca.gov · All data sources

Parameter Symbol Value Unit
Nameplate (STC)
STC Power STC 280.228 W
PTC Power PTC 255.2 W
Open-circuit voltage V_oc_ref 38.3 V
Short-circuit current I_sc_ref 9.34 A
Max-power voltage V_mp_ref 31.7 V
Max-power current I_mp_ref 8.84 A
Fill factor FF 0.7834 —
Efficiency (STC) η 17.01 %
Temperature Coefficients
Isc temperature coefficient alpha_sc 0.00439 A/°C
Voc temperature coefficient beta_oc -0.115283 V/°C
Pmax temperature coefficient gamma_r -0.405 %/°C
NOCT T_NOCT 46.5 °C
Single-Diode (De Soto) Parameters
Modified ideality factor a_ref 1.52317 V
Light-generated current (ref) I_L_ref 9.34327 A
Saturation current (ref) I_o_ref 1.12e-10 A
Series resistance R_s 0.22542 Ω
Shunt resistance (ref) R_sh_ref 643.094 Ω
Cells in series N_s 60 —
CEC Adjust factor Adjust 10.0796 %
Additional Model Sources
Source Model type Fit quality Citation
CEC module list (via SAM library) Default CEC / De Soto single-diode — https://www.energy.ca.gov/media/2367
Sandia PVsyst single-diode fit PVsyst single-diode NMBE Pmp-0.026 Sandia National Laboratories — PVsyst single-diode parameter translation. See data/pvsyst_params.README.md. https://pvpmc.sandia.gov/
Actions
Module Specifications
Technology Mono-c-Si
Bifacial No
BIPV No
Cells in series 60
Module area 1.647 m²
Dimensions 1.66 × 0.992 m
NOCT 46.5 °C
Temp. coefficient of Pmax -0.405 %/°C
Temp. coefficient of Voc -0.301 %/°C
Temp. coefficient of Isc 0.047 %/°C
CEC list Not on the 23 Jun 2026 list
Last listed 16 Nov 2022
Parameters from 16 Nov 2022 list
Annual degradation 0.5%/yr
Measured Data
No measured data yet for this module.
Related Models
Similar Modules

Other manufacturers, same technology and cell count, power within 3 %.

Was this page useful?

© 2026 PV Ivy. All Rights Reserved.