SunPower SPR-E18-295-COM

Mono-c-Si
295 W Pmax
63.3 V Voc
5.83 A Isc
54.2 V Vmp
5.45 A Imp
18.11 % eff.
0.8004 FF
96 cells
IV & PV Curves at STC (1000 W/m², 25 °C)
IV Curves at Multiple Conditions

Irradiance sweep at 25 °C

Temperature sweep at 1000 W/m²

Single-Diode Model Parameters

Source: California Energy Commission module list · retrieved via SAM library · energy.ca.gov · All data sources

Parameter Symbol Value Unit
Nameplate (STC)
STC Power STC 295.39 W
PTC Power PTC 271.1 W
Open-circuit voltage V_oc_ref 63.3 V
Short-circuit current I_sc_ref 5.83 A
Max-power voltage V_mp_ref 54.2 V
Max-power current I_mp_ref 5.45 A
Fill factor FF 0.8004 —
Efficiency (STC) η 18.11 %
Temperature Coefficients
Isc temperature coefficient alpha_sc 0.003599 A/°C
Voc temperature coefficient beta_oc -0.172619 V/°C
Pmax temperature coefficient gamma_r -0.386 %/°C
NOCT T_NOCT 46.0 °C
Single-Diode (De Soto) Parameters
Modified ideality factor a_ref 2.54799 V
Light-generated current (ref) I_L_ref 5.83294 A
Saturation current (ref) I_o_ref 9.24e-11 A
Series resistance R_s 0.2203 Ω
Shunt resistance (ref) R_sh_ref 437.069 Ω
Cells in series N_s 96 —
CEC Adjust factor Adjust 24.295 %
Additional Model Sources
Source Model type Fit quality Citation
CEC module list (via SAM library) Default CEC / De Soto single-diode — https://www.energy.ca.gov/media/2367
Sandia PVsyst single-diode fit PVsyst single-diode NMBE Pmp-0.3486 Sandia National Laboratories — PVsyst single-diode parameter translation. See data/pvsyst_params.README.md. https://pvpmc.sandia.gov/
Actions
Module Specifications
Technology Mono-c-Si
Bifacial No
BIPV No
Cells in series 96
Module area 1.631 m²
Dimensions 1.559 × 1.046 m
NOCT 46.0 °C
Temp. coefficient of Pmax -0.386 %/°C
Temp. coefficient of Voc -0.273 %/°C
Temp. coefficient of Isc 0.062 %/°C
CEC list Not on the 23 Jun 2026 list
Last listed 16 Nov 2022
Parameters from 16 Nov 2022 list
Annual degradation 0.25%/yr