Irradiance sweep at 25 °C
Temperature sweep at 1000 W/m²
Source: California Energy Commission module list · retrieved via SAM library · energy.ca.gov · All data sources
| Parameter | Symbol | Value | Unit |
|---|---|---|---|
| Nameplate (STC) | |||
| STC Power | STC | 435.019 | W |
| PTC Power | PTC | 411.6 | W |
| Open-circuit voltage | V_oc_ref | 40.7 | V |
| Short-circuit current | I_sc_ref | 13.16 | A |
| Max-power voltage | V_mp_ref | 35.31 | V |
| Max-power current | I_mp_ref | 12.32 | A |
| Fill factor | FF | 0.8122 | — |
| Efficiency (STC) | η | 22.9 | % |
| Temperature Coefficients | |||
| Isc temperature coefficient | alpha_sc | 0.005922 | A/°C |
| Voc temperature coefficient | beta_oc | -0.095238 | V/°C |
| Pmax temperature coefficient | gamma_r | -0.28 | %/°C |
| NOCT | T_NOCT | 46.0 | °C |
| Single-Diode (De Soto) Parameters | |||
| Modified ideality factor | a_ref | 1.41763 | V |
| Light-generated current (ref) | I_L_ref | 13.16816 | A |
| Saturation current (ref) | I_o_ref | 4.34e-12 | A |
| Series resistance | R_s | 0.06276 | Ω |
| Shunt resistance (ref) | R_sh_ref | 101.225 | Ω |
| Cells in series | N_s | 112 | — |
| CEC Adjust factor | Adjust | 6.1156 | % |
The CEC list gives 112 cells in series, which puts 0.36 V on each cell. A silicon cell gives 0.55 to 0.80 V, so PV Ivy uses 56 cells in series for the .PAN file and Similar Modules, found from half the CEC count (it counts every half cell).
| Source | Model type | Fit quality | Citation |
|---|---|---|---|
| CEC module list (via SAM library) Default | CEC / De Soto single-diode | — | https://www.energy.ca.gov/media/2367 |
| Sandia PVsyst single-diode fit | PVsyst single-diode | NMBE Pmp-2.2393 | Sandia National Laboratories — PVsyst single-diode parameter translation. See data/pvsyst_params.README.md. https://pvpmc.sandia.gov/ |
2 listings with identical nameplate test data, one per frame, color or backsheet version.