SunPower SPR-X20-245

Mono-c-Si
245 W Pmax
50.8 V Voc
6.08 A Isc
42.8 V Vmp
5.72 A Imp
19.68 % eff.
0.7926 FF
72 cells
IV & PV Curves at STC (1000 W/m², 25 °C)
IV Curves at Multiple Conditions

Irradiance sweep at 25 °C

Temperature sweep at 1000 W/m²

Single-Diode Model Parameters

Source: California Energy Commission module list · retrieved via SAM library · energy.ca.gov · All data sources

Parameter Symbol Value Unit
Nameplate (STC)
STC Power STC 244.816 W
PTC Power PTC 231.7 W
Open-circuit voltage V_oc_ref 50.8 V
Short-circuit current I_sc_ref 6.08 A
Max-power voltage V_mp_ref 42.8 V
Max-power current I_mp_ref 5.72 A
Fill factor FF 0.7926 —
Efficiency (STC) η 19.68 %
Temperature Coefficients
Isc temperature coefficient alpha_sc 0.002432 A/°C
Voc temperature coefficient beta_oc -0.12192 V/°C
Pmax temperature coefficient gamma_r -0.3 %/°C
NOCT T_NOCT 43.6 °C
Single-Diode (De Soto) Parameters
Modified ideality factor a_ref 1.78217 V
Light-generated current (ref) I_L_ref 6.08655 A
Saturation current (ref) I_o_ref 2.48e-12 A
Series resistance R_s 0.40738 Ω
Shunt resistance (ref) R_sh_ref 378.058 Ω
Cells in series N_s 72 —
CEC Adjust factor Adjust 5.3176 %
Additional Model Sources
Source Model type Fit quality Citation
CEC module list (via SAM library) Default CEC / De Soto single-diode — https://www.energy.ca.gov/media/2367
Sandia PVsyst single-diode fit PVsyst single-diode NMBE Pmp-0.0998 Sandia National Laboratories — PVsyst single-diode parameter translation. See data/pvsyst_params.README.md. https://pvpmc.sandia.gov/
Actions
Module Specifications
Technology Mono-c-Si
Bifacial No
BIPV No
Cells in series 72
Module area 1.244 m²
Dimensions 1.559 × 0.798 m
NOCT 43.6 °C
Temp. coefficient of Pmax -0.300 %/°C
Temp. coefficient of Voc -0.240 %/°C
Temp. coefficient of Isc 0.040 %/°C
CEC list Not on the 23 Jun 2026 list
Last listed 16 Nov 2022
Parameters from 16 Nov 2022 list
Annual degradation 0.25%/yr
Measured Data
No measured data yet for this module.
Related Models
Similar Modules

Other manufacturers, same technology and cell count, power within 3 %.

Was this page useful?