SunPower SPR-X21-350-BLK-E-AC
Mono-c-Si
350
W Pmax
68.2
V Voc
6.5
A Isc
57.3
V Vmp
6.11
A Imp
21.48
% eff.
0.7898
FF
96
cells
IV & PV Curves at STC (1000 W/m², 25 °C)
IV Curves at Multiple Conditions
Irradiance sweep at 25 °C
Temperature sweep at 1000 W/m²
Single-Diode Model Parameters
Source: California Energy Commission module list · retrieved via SAM library · energy.ca.gov · All data sources
| Parameter | Symbol | Value | Unit |
|---|---|---|---|
| Nameplate (STC) | |||
| STC Power | STC | 350.103 | W |
| PTC Power | PTC | 327.9 | W |
| Open-circuit voltage | V_oc_ref | 68.2 | V |
| Short-circuit current | I_sc_ref | 6.5 | A |
| Max-power voltage | V_mp_ref | 57.3 | V |
| Max-power current | I_mp_ref | 6.11 | A |
| Fill factor | FF | 0.7898 | — |
| Efficiency (STC) | η | 21.48 | % |
| Temperature Coefficients | |||
| Isc temperature coefficient | alpha_sc | 0.002275 | A/°C |
| Voc temperature coefficient | beta_oc | -0.192324 | V/°C |
| Pmax temperature coefficient | gamma_r | -0.331 | %/°C |
| NOCT | T_NOCT | 45.3 | °C |
| Single-Diode (De Soto) Parameters | |||
| Modified ideality factor | a_ref | 2.48494 | V |
| Light-generated current (ref) | I_L_ref | 6.50662 | A |
| Saturation current (ref) | I_o_ref | 7.67e-12 | A |
| Series resistance | R_s | 0.50604 | Ω |
| Shunt resistance (ref) | R_sh_ref | 496.916 | Ω |
| Cells in series | N_s | 96 | — |
| CEC Adjust factor | Adjust | -2.2934 | % |
Additional Model Sources
| Source | Model type | Fit quality | Citation |
|---|---|---|---|
| CEC module list (via SAM library) Default | CEC / De Soto single-diode | — | https://www.energy.ca.gov/media/2367 |
| Sandia PVsyst single-diode fit | PVsyst single-diode | NMBE Pmp0.0999 | Sandia National Laboratories — PVsyst single-diode parameter translation. See data/pvsyst_params.README.md. https://pvpmc.sandia.gov/ |
Actions
Module Specifications
Technology
Mono-c-Si
Bifacial
No
BIPV
No
Cells in series
96
Module area
1.63 m²
NOCT
45.3 °C
Temp. coefficient of Pmax
-0.331 %/°C
Temp. coefficient of Voc
-0.282 %/°C
Temp. coefficient of Isc
0.035 %/°C
CEC list
Not on the 23 Jun 2026 list
Last listed
16 Nov 2022
Parameters from
16 Nov 2022 list
Annual degradation
0.25%/yr